Key Features
• For Full and Pre-Compliance Testing Including:
MIL-STD 461G
SAEJ1113/27
GMW3097
EUROCAE\RTCA DO160F/G
FORD FMC 1278
IEC 61000-4-21
Electrical Specifications
Frequency Minimum: 200 MHz
Frequency Maximum: 18 GHz (40 GHz)
Physical Specifications
Shield Room Inner Length: 4.83 m
Shield Room Inner Width: 3.61 m
Shield Room Inner Height: 3.05 m
Internal Working Volume Length: 2.20 m
Internal Working Volume Width: 1.60 m
Internal Working Volume Height: 1.50 m
Other Specifications
• Polyethylene Vapor Barrier, 6 mil
• One ETS-Lindgren 3030 'Z' Fold Tuner, Complete with RF Shielded Mounting Bearing Assembly
• Two Ceiling Mounted LED Strip Light Fixtures (Electrical Distribution not included)
• Installation of Enclosure and ETS-Lindgren Equipment
• One ETS-Lindgren Model EMCenter™ with EMControl™ Device Controller Plug-in Module
• One ETS-Lindgren Motor Base with Rotation Speed of 1 to 12 rpm and Mounting Penetration Hardware
• Guaranteed Performance and a Five-year Limited Warranty; One-year Warranty on Doors, Filters and Moving Parts; Two-year Warranty on Optional ETS-Lindgren's Equipment
• One Single-leaf, ETS-Ray Proof Series 201, Recessed Contact Mechanism (RCM), Manually Operated, RF-Shielded Personnel Door, 0.91 m x 2.13 m Clear Opening
• Reverberation Test per IEC 61000-4-21 in Steps from 200 MHz to 1 GHz per the Recommended Procedure
• One Connector Panel, 15.24 cm x 30.48 cm)
• Two Steel Honeycomb Waveguide Air Vents 30.48 cm x 30.48 cm
• Two Connector Panels, 15.24 cm x 30.48 cm Dielectric Floor Underlay, 0.32 cm Thick
• ETS-Lindgren Proprietary TILE! Software to Perform EMS Measurements per SAEJ1113/27, GMW3097, MIL-STD 461G and RTCA DO160F/G, IEC 61000-4-21
• One 10 m Fiber Optic Cable
• Modular Shielded Room and Support Structure
• One Door Maintenance Kit